scimex manages the SeisComP object exchange between two or more different SeisComP systems in real time. scimex may import or export the data to one or several systems. In contrary to scimport the exchange of the SeisComP objects is event based. This means no messages will be exchanged until the exporting system has produced an event.
By default all objects (picks, amplitudes, origins, arrivals, station
magnitudes, magnitudes, magnitude references) are transferred to the other
system. The user can define filters at both the sender and the receiver, to
limit the events for which objects are transferred. Possible filter parameters
are the event location, magnitude, arrival count and agency
(hosts.$name.criteria), plus evaluation mode, evaluation status and
event type (hosts.$name.condition) – see the examples below. scimex
supports two modi: import and export. In export mode scimex collects all objects
relevant for an event (e.g. picks, amplitudes, origins, magnitudes) from
scmaster’s message groups at the source and checks if the filter criteria
match. Once the criteria are fulfilled, the whole package of objects is send
to the scmaster IMPORT group of the receiving system.
At the receiving SeisComP system an instance of scimex runs in import mode. It fetches the whole event information from its own IMPORT group, checks the local filter criteria of the system and sends the collected objects to the different message groups, e.g. Pick, Amplitude, Magnitude, Location. In export mode several recipients can be defined and for each recipient individual filters can be set. To run several instances of scimex on one system, aliases have to be defined, e.g. for import:
seiscomp alias create scimex_import scimex
and for export:
seiscomp alias create scimex_export scimex
Then the configuration can be split into scimex_import.cfg and scimex_export.cfg.
Examples¶
For a push-type configuration, in which the exporting server must be able to connect to the messaging server on the receiving host. On the receiving host:
scimex_import.cfg
connection.username = scimexIm
connection.server = localhost
mode = IMPORT
cleanupinterval = 86400
importHosts = import1
criteria.world.longitude = -180:180
criteria.world.latitude = -90:90
criteria.world.magnitude = 1:9
criteria.world.agencyID = ""
criteria.world.arrivalcount = 15
hosts.import1.address = localhost
# The criterion "world" has been defined above
hosts.import1.criteria = world
# optional and true per default
hosts.import1.filter = false
# optional and true per default
hosts.import1.useDefinedRoutingTable = true
hosts.import1.routingtable = Pick:IMPORT,StationAmplitude:IMPORT,
Origin:LOCATION,Arrival:LOCATION,
StationMagnitude:MAGNITUDE,
Magnitude:MAGNITUDE,
StationMagnitudeContribution:MAGNITUDE,
OriginReference:EVENT,Event:EVENT
In this example, Pick and StationAmplitude objects are sent to the receiving system’s IMPORT group to avoid interfering with the receiving system’s picking.
On the sending system, only those events with a high enough magnitude and enough arrivals, and with the AgencyID “GFZ” are exported: scimex_export.cfg
connection.username="scimexEx"
connection.server = localhost
mode = EXPORT
cleanupinterval = 7200
exportHosts = exp1, exp2
# Match everything with magnitude above or equal 5
# and with more than 25 phases which comes from
# agency GFZ.
criteria.globalM5.latitude = -90:90
criteria.globalM5.longitude = -180:180
criteria.globalM5.magnitude = 5:10
criteria.globalM5.arrivalcount = 25
criteria.globalM5.agencyID = GFZ
# Export to a system which still runs a very old version. The
# messages need to be converted.
hosts.exp1.address = 192.168.0.3
hosts.exp1.criteria = globalM5
hosts.exp1.conversion = imexscdm0.51
hosts.exp2.address = 192.168.0.4
hosts.exp2.criteria = globalM5
condition complements criteria with fields criteria cannot express:
evaluation mode, evaluation status and event type. It is additive – if both
are set for a host, an origin must pass both – and can also be used on its
own. To export only reviewed/final solutions from exp1, never a false
detection, in addition to the globalM5 criteria already defined above:
hosts.exp1.condition = "mode == 'manual' && status == 'final' && \
type != 'not existing'"
The condition syntax, operators and key names (mag/magnitude,
lat/latitude, lon/longitude, depth, agencyid,
author, mode/evaluationmode, status/evaluationstatus,
type, typecertainty) match the ga-mla magselect scevent plugin
and scolv/scesv’s eventlist.highlight feature.
Module Configuration¶
etc/defaults/global.cfgetc/defaults/scimex.cfgetc/global.cfgetc/scimex.cfg~/.seiscomp/global.cfg~/.seiscomp/scimex.cfgscimex inherits global options.
- mode¶
Type: string
Mode of operation. Options are IMPORT or EXPORT.
- cleanupinterval¶
Type: double
Unit: s
Cache lifetime for objects.
- subscriptions¶
Type: list:string
Only used in export mode. A list of message groups to subscribe.
- conversion¶
Type: string
Used only in import mode. It defines the source format of the messages that need to be converted. Currently the import of SeisComP datamodel version 0.51 (imexscdm0.51) is supported which was used in release Barcelona (2008).
- exportHosts¶
Type: list:string
A list of hosts profiles to be considered for exporting. These are used in hosts.$name directives (see below) to define addresses, filter criteria, etc. applicable to each recipient.
- importHosts¶
Type: list:string
A list of hosts profiles to be considered for importing. These are used with hosts.$name directives similarly to exportHosts.
Note
criteria.$name.* A definition of an event filter. $name is a placeholder for the name to be used.
- criteria.$name.latitude¶
Type: tuple:double
Pair of doubles that defines the latitude range. Example: -90:90.
- criteria.$name.longitude¶
Type: tuple:double
Pair of doubles that defines the longitude range. Example: -180:180.
- criteria.$name.magnitude¶
Type: tuple:double
Pair of doubles that defines the magnitude range. Example: 3:10.
- criteria.$name.arrivalcount¶
Type: int
Number of minimum arrivals.
- criteria.$name.agencyID¶
Type: list:string
White list of AgencyIDs (the agency identifier which appears in the objects sent over the export-import link).
Note
hosts.$name.* A sink definition used for either import or export. $name is a placeholder for the name to be used.
- hosts.$name.address¶
Type: string
Address of a sink, as a host name with an optional port number e.g. ‘address = 192.168.1.1’ or ‘address = somewhere.com:4803’
- hosts.$name.criteria¶
Type: string
Defining filter criteria name for sink, e.g. criteria = world-xxl. The criteria must be defined in the criteria. * configuration lines.
- hosts.$name.condition¶
Type: string
A Utils::V2::LeParser logical expression, evaluated in addition to criteria (if both are set, an origin must pass both). Unlike criteria it can filter on evaluation mode/status and event type -- e.g. only exporting reviewed/final solutions and never a false detection. The key names and aliases match the ga-mla "magselect" scevent plugin and scolv/scesv’s eventlist.highlight feature: mag/magnitude, lat/latitude, lon/longitude, depth, agencyid, author, mode (alias: evaluationmode), status (alias: evaluationstatus), type, typecertainty. String values must be single-quoted; unset fields are treated as null (!= returns true, == returns false).
Example, exporting only reviewed/final M4.5+ solutions in a region of interest while excluding events flagged as a false detection: condition = "mag >= 4.5 && lat >= 30 && lat <= 45 && lon >= 20 && lon <= 45 && mode == ‘manual’ && status == ‘final’ && type != ‘not existing’"
- hosts.$name.filter¶
Default:
trueType: boolean
Enable/disable filtering based on criteria and/or condition. If set to false, all events will pass, even if criteria and/or condition are defined. If set to true, at least one of criteria or condition must be defined.
- hosts.$name.conversion¶
Type: string
Optional target format for export.
- hosts.$name.useDefinedRoutingTable¶
Default:
falseType: boolean
Enable/disable defined routing tables.
- hosts.$name.routingTable¶
Type: list:string
Defining routing tables in the meaning of mapping objects to message groups. Example: Pick:NULL, StationAmplitude:NULL, Origin:LOCATION, StationMagnitude: MAGNITUDE, NetworkMagnitude:MAGNITUDE, MagnitudeReference:MAGNITUDE, OriginReference:EVENT, Event:EVENT. Specifying NULL for the message group causes messages to be thrown away/dropped/discarded.
Command-Line Options¶
scimex [options]
Generic¶
- -h, --help¶
Show help message.
- -V, --version¶
Show version information.
- --config-file file¶
The alternative module configuration file. When this option is used, the module configuration is only read from the given file and no other configuration stage is considered. Therefore, all configuration including the definition of plugins must be contained in that file or given along with other command-line options such as --plugins.
- --plugins arg¶
Load given plugins.
- -D, --daemon¶
Run as daemon. This means the application will fork itself and doesn’t need to be started with &.
- --auto-shutdown arg¶
Enable/disable self-shutdown because a master module shutdown. This only works when messaging is enabled and the master module sends a shutdown message (enabled with --start-stop-msg for the master module).
- --shutdown-master-module arg¶
Set the name of the master-module used for auto-shutdown. This is the application name of the module actually started. If symlinks are used, then it is the name of the symlinked application.
- --shutdown-master-username arg¶
Set the name of the master-username of the messaging used for auto-shutdown. If "shutdown-master-module" is given as well, this parameter is ignored.
Verbosity¶
- --verbosity arg¶
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info, 4:debug.
- -v, --v¶
Increase verbosity level (may be repeated, e.g., -vv).
- -q, --quiet¶
Quiet mode: no logging output.
- --component arg¶
Limit the logging to a certain component. This option can be given more than once.
- -s, --syslog¶
Use syslog logging backend. The output usually goes to /var/lib/messages.
- -l, --lockfile arg¶
Path to lock file.
- --console arg¶
Send log output to stdout.
- --debug¶
Execute in debug mode. Equivalent to --verbosity=4 --console=1 .
- --log-file arg¶
Use alternative log file.
Messaging¶
- -u, --user arg¶
Overrides configuration parameter
connection.username.
- -H, --host arg¶
Overrides configuration parameter
connection.server.
- -t, --timeout arg¶
Overrides configuration parameter
connection.timeout.
- -g, --primary-group arg¶
Overrides configuration parameter
connection.primaryGroup.
- -S, --subscribe-group arg¶
A group to subscribe to. This option can be given more than once.
- --content-type arg¶
Overrides configuration parameter
connection.contentType.Default:
binary
- --start-stop-msg arg¶
Default:
0Set sending of a start and a stop message.
SCIMEX¶
- --print-default-routingtable¶
Print the default object routing table.